20kWh Floor-Standing LiFePO4 Home Battery

For home solar and backup.

Key product details

The ZJBESS LS20KW is a 20kWh battery for home solar storage: a 51.2V 400Ah LiFePO4 tower with BYD Blade cells. The slim tower stores 20.48kWh on a 353 × 320mm footprint, runs a 1kW load for about 17 hours and carries a 48V inverter up to 8kW. Built and tested in our factory in Shandong, China.

  • 20.48kWh · 51.2V 400Ah · 200A continuous discharge
  • BYD Blade cells · 8,000+ cycles · 10-year warranty
  • 18 inverter protocols on the 4.3-inch touch screen · 3A active balancing
  • Up to 15 units in parallel for 307.2kWh · 18.43kWh LS18KW option
LS20KW at a glance

20kWh in a tower the size of a fridge column

The LS20KW is the slim floor-standing 20kWh model in the ZJBESS home battery range. Sixteen BYD Blade 3.2V 400Ah LiFePO4 cells in one series string (16S1P) form the 51.2V 400Ah pack inside a 1240mm-tall tower that stands on a 353 × 320mm footprint. The smart BMS has the largest screen in the range, a 4.3-inch touch screen, plus Bluetooth and Wi-Fi.

It is a battery-only product. Pair it with any 48V hybrid or off-grid inverter that uses one of the 18 built-in battery protocols, or with a ZJBESS inverter. For a little less energy in the same tower there is the 18.43kWh LS18KW; for 15kWh on casters, the LS15KW; for 40kWh in one cabinet, the LS40KW.

  • Run a whole home through the night, with room for daytime AC
  • Stand in a corner: 0.11m² of floor for 20kWh
  • No wall bracket and no rack
  • Grow from 20.48kWh to 307.2kWh with the same SKU
20.48kWhNominal energy
51.2V48V system
400AhBYD Blade cells
200AContinuous discharge
4.3-inchTouch screen
15 units307.2kWh in parallel
8,000+Cycles
10 yearsWarranty
Capacity in practice

How long will a 20kWh battery last?

About 17kWh reaches the AC loads from one full LS20KW. That runs a typical home through the evening and night with air conditioning, or a full day of essentials during long outages.

Average AC loadTypical loadsRuntime, 1 unitRuntime, 2 units
500WLights, router, fridge, TV34 h68 h
1,000W+ laptop, freezer, water pump cycling17.0 h34 h
2,000W+ 1.5HP inverter air conditioner8.5 h17.0 h
3,000WWhole-home evening use5.7 h11.3 h
5,000WHeavy daytime use, two AC units3.4 h6.8 h

How many solar panels charge a 20kWh battery? About 5.1kW of PV, or 10 × 550W panels, refills one LS20KW in a day with 5 peak sun hours (20.48kWh ÷ 5h ÷ 0.8 system factor = 5.12kW). Add the panels needed for daytime loads on top.

Illustrative home backup scene with a LS20KW battery, lights, refrigerator and TV running
Installation

A slim tower: small footprint, short cable run

The LS20KW stands upright in a corner or against a wall beside the inverter. The 353mm width passes any door; plan the move for 175kg.

Illustrative LS20KW scene: move it upright

Move it upright

Remove the crate and stand the 175kg tower upright with a hand truck or two people. It is 353mm wide and 320mm deep.

Illustrative LS20KW scene: stand it in the corner

Stand it in the corner

Place it on a level floor beside the inverter. A tall unit should be secured to the wall against tipping, as with any tall equipment.

ZJBESS floor-standing batteries standing side by side in the workshop, each with a green status ring

Add towers side by side

Expansion is another tower next to the first, with parallel power and communication cables. Two towers take 0.23m² for 41kWh.

Smart BMS

Tap. See. Control. A BMS your installers can read on site

CAN or RS485 to the inverter, Bluetooth and Wi-Fi to the ZJBESS app, and a 4.3-inch touch screen where the installer picks the inverter protocol.

Protocol Direct Select

Pick the inverter brand on the 4.3-inch screen, the largest in the ZJBESS home range.

Active balancing

Moves up to 3A between cells, so the large 400Ah pack stays matched charge after charge.

Cell-level alarms

Voltage of all 16 cells and four cell temperature sensors, on the screen or in the app.

Remote service

Wi-Fi monitoring of SOC, alarms and history from your office.

Illustration: selecting the CAN or RS485 protocol on the battery touch screen
Concept of a LS20KW battery, hybrid inverter and phone monitoring dashboard

Eight protections, set at the factory

Overcharge

Charging stops at 58.4V

Over-discharge

Recommended cut-off 44.8V, BMS cut-off 43.2V

Overcurrent

200A continuous (0.5C); trips at 210A after 2s

Short circuit

Disconnect within 100µs at 480A or more

Low-temperature charge

Charging blocked below 0°C; optional heating pads

High temperature

Charging stops above 50°C, discharge above 55°C

Overload

Peak up to about 11kW for under 2s

Cell imbalance

Active balancing up to 3A, alarm per cell

Performance

Key performance advantages of the LS20KW

8,000+
cycles

BYD Blade cells rated at 25°C, 0.5C and 100% DOD with more than 80% capacity left. One full cycle a day is more than 21 years, so the 10-year warranty is the limit, not the cells.

200A
continuous

Only 0.5C on 400Ah, so the cells run cool at full current. Carries an 8kW inverter at full output (181A at 48V, 92% efficiency).

307.2
kWh in parallel

Up to 15 identical units on one 51.2V bus. Energy and current add up, voltage stays the same.

0.11m²
footprint

20.48kWh on 353 × 320mm of floor: about 180kWh per square metre of floor space.

LS20KW towers connected to charge–discharge test equipment in the ZJBESS factory

Why 8,000+ cycles matter to your customer

At one full cycle a day, 8,000 cycles is more than 21 years of cycling, against 500 to 1,500 cycles for lead-acid at 50% DOD. The 10-year warranty, not cell wear, sets the planning life, and shallower daily cycles extend it further. Each tower is charge–discharge tested before it leaves the factory.

Inside the battery

BYD Blade cells in a slim tower

Sixteen 3.2V 400Ah Blade cells form one series string (16S1P): no parallel cell groups inside the pack, and fewer connections to check.

  • BYD Blade cells as standard. New 3.2V 400Ah LiFePO4 cells rated for 8,000+ cycles. Other Grade A cells are available on request.
  • Active balancing. The BMS moves up to 3A between cells, starting at 3.40V per cell with more than 30mV difference.
  • 4.3-inch screen. The largest display in the ZJBESS home range, set at a readable height on the tower.
Inside the LS20KW: LiFePO4 cell pack, busbars and BMS wiring
LS20KW top panel with CAN, RS485 and RS232 ports, dry contact, breaker and DC terminals
Open LS20KW cabinet showing the cell pack and BMS wiring
Illustration: phone app showing the voltage of all 16 cells (demo data)
Inverter compatibility

Which inverters work with the LS20KW?

Protocols for 18 inverter brands are built in, so the inverter charges by the LS20KW BMS limits, not a fixed voltage.

Pylontech protocolGrowattVoltronic (Axpert)LuxpowerWOWSchneiderDeyeVictronSorotecSMAGoodWeStuderMUSTGinlong (Solis)SenergyTBBMegarevoAiswei

One LS20KW pairs with a 6–8kW hybrid inverter and stores a full day of a 5kW array; two towers suit the ZJBESS 13.2kW hybrid inverter.

Select the protocol

Choose the inverter brand on the 4.3-inch screen at chest height.

Connect CAN or RS485

Connect the tower communication port to the inverter BMS port over CAN or RS485.

Set lithium mode

Set the inverter battery type to lithium / BMS communication.

Check the readings

Confirm the inverter reads SOC and the 400Ah pack limits.

Pre-loaded for your market. Tell us the inverters you sell and our BMS engineers set the protocol before the LS20KW is crated. For a brand outside the list, send the model and firmware and we build the match.

LS20KW installed below a ZJBESS hybrid inverter at a customer site in the United Arab Emirates
Battery packs and electrical test equipment on the ZJBESS workshop floor
Applications

Where the LS20KW is used

ZJBESS floor-standing battery installed beside a wall-mounted inverter at a customer home

Whole-home backup

One LS20KW runs a family home with a 1.5HP air conditioner for 10–12 hours of the night; two towers cover a full night and long outages.

Illustrative LS20KW scene: villas and large homes

Villas and large homes

Pair one tower with a 6–8kW hybrid inverter and 5kW of PV to store a full day of solar; add towers for larger villas.

Illustrative LS20KW scene: clinics and small offices

Clinics and small offices

Vaccine fridges, lights, computers and routers kept on without generator fuel or noise. 17kWh at the loads covers a full clinic night.

Scalability

One tower from 20kWh to 300kWh

Up to 15 LS20KW units run in parallel on one 51.2V bus. Distributors stock one tower and quote every system size from it.

UnitsNominal energyAt the AC loadsContinuous currentTypical system
120.48kWh17kWh200AHome with a 5–8kW inverter
240.96kWh33.9kWh400ALarge home, 10–12kW inverter
361.44kWh50.9kWh600AVilla with daytime AC
5102.4kWh84.8kWh1,000AShop, clinic, guesthouse
10204.8kWh169.6kWh2,000AMulti-inverter site
15307.2kWh254.4kWh3,000AMaximum parallel bank
Illustrative composite: two LS20KW batteries in parallel below a wall-mounted inverter
Know before you buy

LS20KW limits your installers should know

20.48kWh is nominal

About 17kWh reaches the AC loads after the discharge window and inverter losses. We size on that figure, not the nameplate.

175kg and 1.24m tall

Move it with a hand truck or two people, place it on a level floor and secure it to the wall against tipping.

8kW per tower

More energy does not mean more power. One tower carries up to about 8kW; above that, connect two in parallel.

Same model in parallel

Expand only with LS20KW units. Mixing LS20KW with LS18KW, LS15KW or other brands in one bank is not supported.

Charge above 0°C only

The tower discharges down to −20°C but will not charge below 0°C unless the optional heating pads are fitted. Install it inside the home in cold climates.

Install under cover

Install indoors or under cover, out of direct sun and rain. Sun on a tall white tower heats the cells.