20kWh Floor-Standing LiFePO4 Home Battery
For home solar and backup.
Key product details
The ZJBESS LS20KW is a 20kWh battery for home solar storage: a 51.2V 400Ah LiFePO4 tower with BYD Blade cells. The slim tower stores 20.48kWh on a 353 × 320mm footprint, runs a 1kW load for about 17 hours and carries a 48V inverter up to 8kW. Built and tested in our factory in Shandong, China.
- 20.48kWh · 51.2V 400Ah · 200A continuous discharge
- BYD Blade cells · 8,000+ cycles · 10-year warranty
- 18 inverter protocols on the 4.3-inch touch screen · 3A active balancing
- Up to 15 units in parallel for 307.2kWh · 18.43kWh LS18KW option
20kWh in a tower the size of a fridge column
The LS20KW is the slim floor-standing 20kWh model in the ZJBESS home battery range. Sixteen BYD Blade 3.2V 400Ah LiFePO4 cells in one series string (16S1P) form the 51.2V 400Ah pack inside a 1240mm-tall tower that stands on a 353 × 320mm footprint. The smart BMS has the largest screen in the range, a 4.3-inch touch screen, plus Bluetooth and Wi-Fi.
It is a battery-only product. Pair it with any 48V hybrid or off-grid inverter that uses one of the 18 built-in battery protocols, or with a ZJBESS inverter. For a little less energy in the same tower there is the 18.43kWh LS18KW; for 15kWh on casters, the LS15KW; for 40kWh in one cabinet, the LS40KW.
- Run a whole home through the night, with room for daytime AC
- Stand in a corner: 0.11m² of floor for 20kWh
- No wall bracket and no rack
- Grow from 20.48kWh to 307.2kWh with the same SKU
How long will a 20kWh battery last?
About 17kWh reaches the AC loads from one full LS20KW. That runs a typical home through the evening and night with air conditioning, or a full day of essentials during long outages.
| Average AC load | Typical loads | Runtime, 1 unit | Runtime, 2 units |
|---|---|---|---|
| 500W | Lights, router, fridge, TV | 34 h | 68 h |
| 1,000W | + laptop, freezer, water pump cycling | 17.0 h | 34 h |
| 2,000W | + 1.5HP inverter air conditioner | 8.5 h | 17.0 h |
| 3,000W | Whole-home evening use | 5.7 h | 11.3 h |
| 5,000W | Heavy daytime use, two AC units | 3.4 h | 6.8 h |
How many solar panels charge a 20kWh battery? About 5.1kW of PV, or 10 × 550W panels, refills one LS20KW in a day with 5 peak sun hours (20.48kWh ÷ 5h ÷ 0.8 system factor = 5.12kW). Add the panels needed for daytime loads on top.

A slim tower: small footprint, short cable run
The LS20KW stands upright in a corner or against a wall beside the inverter. The 353mm width passes any door; plan the move for 175kg.

Move it upright
Remove the crate and stand the 175kg tower upright with a hand truck or two people. It is 353mm wide and 320mm deep.

Stand it in the corner
Place it on a level floor beside the inverter. A tall unit should be secured to the wall against tipping, as with any tall equipment.

Add towers side by side
Expansion is another tower next to the first, with parallel power and communication cables. Two towers take 0.23m² for 41kWh.
Tap. See. Control. A BMS your installers can read on site
CAN or RS485 to the inverter, Bluetooth and Wi-Fi to the ZJBESS app, and a 4.3-inch touch screen where the installer picks the inverter protocol.
Protocol Direct Select
Pick the inverter brand on the 4.3-inch screen, the largest in the ZJBESS home range.
Active balancing
Moves up to 3A between cells, so the large 400Ah pack stays matched charge after charge.
Cell-level alarms
Voltage of all 16 cells and four cell temperature sensors, on the screen or in the app.
Remote service
Wi-Fi monitoring of SOC, alarms and history from your office.


Eight protections, set at the factory
Charging stops at 58.4V
Recommended cut-off 44.8V, BMS cut-off 43.2V
200A continuous (0.5C); trips at 210A after 2s
Disconnect within 100µs at 480A or more
Charging blocked below 0°C; optional heating pads
Charging stops above 50°C, discharge above 55°C
Peak up to about 11kW for under 2s
Active balancing up to 3A, alarm per cell
Key performance advantages of the LS20KW
BYD Blade cells rated at 25°C, 0.5C and 100% DOD with more than 80% capacity left. One full cycle a day is more than 21 years, so the 10-year warranty is the limit, not the cells.
Only 0.5C on 400Ah, so the cells run cool at full current. Carries an 8kW inverter at full output (181A at 48V, 92% efficiency).
Up to 15 identical units on one 51.2V bus. Energy and current add up, voltage stays the same.
20.48kWh on 353 × 320mm of floor: about 180kWh per square metre of floor space.

Why 8,000+ cycles matter to your customer
At one full cycle a day, 8,000 cycles is more than 21 years of cycling, against 500 to 1,500 cycles for lead-acid at 50% DOD. The 10-year warranty, not cell wear, sets the planning life, and shallower daily cycles extend it further. Each tower is charge–discharge tested before it leaves the factory.
BYD Blade cells in a slim tower
Sixteen 3.2V 400Ah Blade cells form one series string (16S1P): no parallel cell groups inside the pack, and fewer connections to check.
- BYD Blade cells as standard. New 3.2V 400Ah LiFePO4 cells rated for 8,000+ cycles. Other Grade A cells are available on request.
- Active balancing. The BMS moves up to 3A between cells, starting at 3.40V per cell with more than 30mV difference.
- 4.3-inch screen. The largest display in the ZJBESS home range, set at a readable height on the tower.




Which inverters work with the LS20KW?
Protocols for 18 inverter brands are built in, so the inverter charges by the LS20KW BMS limits, not a fixed voltage.
One LS20KW pairs with a 6–8kW hybrid inverter and stores a full day of a 5kW array; two towers suit the ZJBESS 13.2kW hybrid inverter.
Select the protocol
Choose the inverter brand on the 4.3-inch screen at chest height.
Connect CAN or RS485
Connect the tower communication port to the inverter BMS port over CAN or RS485.
Set lithium mode
Set the inverter battery type to lithium / BMS communication.
Check the readings
Confirm the inverter reads SOC and the 400Ah pack limits.
Pre-loaded for your market. Tell us the inverters you sell and our BMS engineers set the protocol before the LS20KW is crated. For a brand outside the list, send the model and firmware and we build the match.


Where the LS20KW is used

Whole-home backup
One LS20KW runs a family home with a 1.5HP air conditioner for 10–12 hours of the night; two towers cover a full night and long outages.

Villas and large homes
Pair one tower with a 6–8kW hybrid inverter and 5kW of PV to store a full day of solar; add towers for larger villas.

Clinics and small offices
Vaccine fridges, lights, computers and routers kept on without generator fuel or noise. 17kWh at the loads covers a full clinic night.
One tower from 20kWh to 300kWh
Up to 15 LS20KW units run in parallel on one 51.2V bus. Distributors stock one tower and quote every system size from it.
| Units | Nominal energy | At the AC loads | Continuous current | Typical system |
|---|---|---|---|---|
| 1 | 20.48kWh | 17kWh | 200A | Home with a 5–8kW inverter |
| 2 | 40.96kWh | 33.9kWh | 400A | Large home, 10–12kW inverter |
| 3 | 61.44kWh | 50.9kWh | 600A | Villa with daytime AC |
| 5 | 102.4kWh | 84.8kWh | 1,000A | Shop, clinic, guesthouse |
| 10 | 204.8kWh | 169.6kWh | 2,000A | Multi-inverter site |
| 15 | 307.2kWh | 254.4kWh | 3,000A | Maximum parallel bank |

LS20KW limits your installers should know
20.48kWh is nominal
About 17kWh reaches the AC loads after the discharge window and inverter losses. We size on that figure, not the nameplate.
175kg and 1.24m tall
Move it with a hand truck or two people, place it on a level floor and secure it to the wall against tipping.
8kW per tower
More energy does not mean more power. One tower carries up to about 8kW; above that, connect two in parallel.
Same model in parallel
Expand only with LS20KW units. Mixing LS20KW with LS18KW, LS15KW or other brands in one bank is not supported.
Charge above 0°C only
The tower discharges down to −20°C but will not charge below 0°C unless the optional heating pads are fitted. Install it inside the home in cold climates.
Install under cover
Install indoors or under cover, out of direct sun and rain. Sun on a tall white tower heats the cells.
How every LS20KW is built and tested
LS20KW and LS18KW towers pass the same eight stations in our factory in Shandong, China. The 1240mm tower is built and tested standing upright, then crated for shipping.

Incoming cell inspection
The 400Ah cells for each LS20KW are scanned on arrival and checked for voltage, internal resistance and casing damage.

Sorting & matching
Sixteen series positions are filled with matched 400Ah cells, so the large pack needs less balancing in service.

Module assembly
The 16 Blade cells are stacked, fixed and connected with busbars into a tall, narrow 51.2V 400Ah module.

BMS wiring
Sampling leads and temperature sensors run up to the BMS behind the 4.3-inch screen.

Cabinet integration
Pack, BMS, breaker and screen go into the 353 × 320mm tower.

Charge–discharge aging
Each LS20KW is fully charged and discharged, and capacity and aging curve are saved per serial number.

Final inspection & protocol
Screen, communication and insulation are rechecked, and your inverter protocol is set.

Crating & documents
The tower ships in a 1340 × 480 × 530mm UN3480 wooden crate with cables, manual and its QC pack.
Distributor terms for the LS20KW
Our published terms for distributors, installers and EPC buyers, written into every LS20KW quotation.
Standard LS20KW and LS18KW orders leave the factory within 15 working days of the confirmed order.
Your logo and colour on the LS20KW tower and boot screen from 3 units.
Every LS20KW service request is answered within 24 hours, with a handling plan within 3 days.
LS20KW crates (1340 × 480 × 530mm, 195kg) load about 48–64 per 20ft container. The loading plan for your order gives the final count.
Included in the LS20KW quotation
- LS20KW or LS18KW with your inverter protocol pre-loaded
- Power and communication cables, manual
- Per-unit QC pack and configuration record
- UN38.3 (SCT2604151615-S01), MSDS and certificates
Payment and order options
- One tower for your inverter test
- Pallets or mixed containers with LS15KW and inverters
- Alibaba Trade Assurance or letter of credit (L/C)
LS20KW OEM and ODM under your brand
Colour, logo, boot screen, app, carton and manual change for your market; cells, BMS and tests stay the same. For a full range, pair the LS20KW with the LS15KW on casters, the 40kWh LS40KW or the wall-mounted BG10KW.
Brief
Market, inverters, quantity
Artwork
Tower colour and logo proofs
Sample
One branded tower to test
Production
Same eight stations and records
Inspection
Photo, video or third-party check
Shipping
Crated, tracked




ZJBESS floor-standing batteries in the field
Nigeria

Philippines

United States
LS20KW and LS18KW specifications
Two tower capacities on the same BMS, 4.3-inch touch screen and LiFePO4 cell platform. Pick the energy your customers need; the electrical limits stay the same.
| Model | LS20KW · This page20.48kWh51.2V 400AhDatasheet PDF | LS18KW18.43kWh51.2V 360AhDatasheet PDF |
|---|---|---|
| Battery & energy | ||
| Nominal energy | 20.48kWh | 18.43kWh |
| Nominal capacity | 400Ah | 360Ah |
| Cell configuration | 16S1P · BYD Blade 400Ah | 16S LiFePO4 · 360Ah |
| Nominal voltage | 51.2V | |
| Chemistry | LiFePO4, Grade A cells (BYD Blade in LS20KW) | |
| Recommended SOC window | 0–100% | |
| Internal resistance | ≤50mΩ @ 50% SOC | |
| Cycle life | 8,000+ cycles (25°C, 0.5C, 100% DOD, >80% capacity) | |
| Charge & discharge | ||
| Charge voltage (recommended / BMS cut-off) | 57.6V / 58.4V | |
| Low-voltage disconnect (recommended / BMS) | 44.8V / 43.2V | |
| Cell balancing | Active, up to 3A (from 3.40V per cell) | |
| Charge / continuous discharge current | 100A recommended (200A on request) / 200A | |
| Load power (recommended / ultimate) | 8.2kW / about 11kW for under 2s | |
| Communication & expansion | ||
| Inverter communication | CAN / RS485 / RS232 | |
| Wireless | Bluetooth (app) · Wi-Fi (remote monitoring) | |
| Display | 4.3-inch touch screen | |
| Inverter protocols | 18 brands built in, selected on screen | |
| Max. parallel | 15 units | |
| Max. parallel energy | 307.2kWh | 276.4kWh |
| Environment | ||
| Temperature (charge / discharge / storage) | 0 to 50°C / −20 to 55°C / −20 to 30°C (long term) | |
| Low-temperature charging | Optional heating pads | |
| Installation location | Indoors or under cover | |
| Mechanical, shipping & warranty | ||
| Dimensions | 353 × 320 × 1240mm (W × D × H) | 353 × 320 × 1240mm (W × D × H) |
| Net / gross weight | 175kg / 195kg | On request |
| Installation | Floor-standing | |
| Packing | Wooden crate 1340 × 480 × 530mm, UN3480 | |
| Transport and EU documents | UN38.3 (SCT2604151615-S01), MSDS, CE EMC, RoHS | |
| Warranty | 10 years, free replacement of covered faults | |
Certificates
Ready for market entry with UN38.3, MSDS, CE EMC and RoHS test reports for ZJBESS 51.2V LiFePO4 batteries. For the 51.2V 400Ah battery: UN38.3 test report SCT2604151615-S01 (May 2026, CNAS lab), MSDS SCT2604151615-S03 and sea-freight classification SCT2604151615-S04 (UN3480, Class 9). Report numbers and model scope come with your quotation.
LS20KW 20kWh battery FAQs
What distributors, installers and EPC buyers ask us before ordering.
LS20KW or LS15KW: which should I stock?
Both are floor-standing on the same BMS platform. The LS15KW stores 15.36kWh in a 1000mm-high cabinet on casters (121kg). The LS20KW stores 20.48kWh in a 1240mm slim tower on a 353 × 320mm footprint (175kg net) with BYD Blade cells and a 4.3-inch screen. The two are not mixed in one bank. Choose LS20KW for homes with night-time air conditioning or tight floor space.
How long will a 20kWh battery last?
Using 20.48kWh × 90% discharge depth × 92% inverter efficiency gives about 17kWh of usable AC energy: roughly 17 hours at 1kW or 5.7 hours at 3kW. Each tower supports up to 8kW continuous output. Actual runtime depends on the load, inverter efficiency and operating conditions.
Can one LS20KW run air conditioning overnight?
A 1.5HP inverter air conditioner averages roughly 0.8–1.2kW through a night. With lights, fridge and fans, one LS20KW covers about 10–12 hours of that load; two towers give a full night with margin.
Does the LS20KW need to be fixed to the wall?
It stands on its own base. Because it is 1240mm tall, secure it to the wall against tipping, especially in homes with children or in earthquake zones, and place it on a level floor.
What size inverter can one LS20KW run?
Up to 8kW continuous. At 200A the 400Ah pack works at only 0.5C, so the cells stay cool at full output. For 10–12kW, connect two towers.
What cells does the LS20KW use, and how long do they last?
Sixteen BYD Blade 3.2V 400Ah LiFePO4 cells as standard, rated for more than 8,000 cycles at 25°C, 0.5C and 100% DOD with over 80% capacity remaining. Other Grade A cells are available on request.
Can the LS20KW charge below 0°C?
Not in the standard version: the BMS blocks charging below 0°C to protect the cells. With the optional heating pads, the BMS warms the cells first and then starts charging. Set the inverter low-voltage cut-off to 44.8V; the BMS protects the pack at 43.2V.
LS20KW or LS18KW: what is the difference?
Same tower, BMS and 4.3-inch screen, same 353 × 320 × 1240mm size. The LS20KW holds 400Ah (20.48kWh); the LS18KW holds 360Ah (18.43kWh). The two are not mixed in one bank.
How many LS20KW can run in parallel?
Up to 15 identical towers, for 307.2kWh. Two give 40.96kWh, three 61.44kWh. Two towers stand on 0.23m² of floor.
How many solar panels charge an LS20KW?
About 5.1kW of PV, or ten 550W panels, with 5 peak sun hours (20.48kWh ÷ 5h ÷ 0.8 = 5.12kW).
Which inverters are compatible with the LS20KW?
18 brands are built into the BMS, including Pylontech protocol, Growatt, Voltronic, Deye, Victron, SMA and Solis. Connect over CAN or RS485. See our inverter compatibility guide.
How many LS20KW fit in a 20ft container?
About 48–64 LS20KW fit a 20GP container in 1340 × 480 × 530mm UN3480 crates; the loading plan for your order gives the final count. The 51.2V 400Ah battery is covered by UN38.3 test report SCT2604151615-S01. Standard orders dispatch within 15 working days.
What warranty does the LS20KW have?
10 years, with free replacement of covered faults, an answer within 24 hours and a handling plan within 3 days. How warranty claims work
LS20KW documents
| Document | What it shows | How to get it |
|---|---|---|
| LS20KW datasheet | Electrical ratings, temperatures, dimensions, compatible inverters | Download PDF |
| LS18KW datasheet | Electrical ratings, temperatures, dimensions, compatible inverters | Download PDF |
| Per-unit QC pack | Serial number, cell QR codes, IR matching report, aging curve | In every LS20KW crate |
| Configuration record | BMS version, inverter model and firmware, protocol and settings | With your order |
| UN38.3 test summary, MSDS, CE EMC and RoHS certificates | For customs and tenders | With your quotation |
| LS20KW manual and warranty card | Installation, settings, maintenance, claim process | With your quotation |
Guides for your sales team: sizing · inverter compatibility · rack vs wall vs floor-standing · sample acceptance test · LiFePO4 supplier checklist
Get a Wholesale Quote
Tell us your required battery capacity, application and inverter model. We will confirm the suitable configuration before quotation.